Merge tag 'batadv-next-for-davem-20190213' of git://git.open-mesh.org/linux-merge
[sfrench/cifs-2.6.git] / Documentation / networking / device_drivers / intel / ixgbe.rst
1 .. SPDX-License-Identifier: GPL-2.0+
2
3 =============================================================================
4 Linux* Base Driver for the Intel(R) Ethernet 10 Gigabit PCI Express Adapters
5 =============================================================================
6
7 Intel 10 Gigabit Linux driver.
8 Copyright(c) 1999-2018 Intel Corporation.
9
10 Contents
11 ========
12
13 - Identifying Your Adapter
14 - Command Line Parameters
15 - Additional Configurations
16 - Known Issues
17 - Support
18
19 Identifying Your Adapter
20 ========================
21 The driver is compatible with devices based on the following:
22
23  * Intel(R) Ethernet Controller 82598
24  * Intel(R) Ethernet Controller 82599
25  * Intel(R) Ethernet Controller X520
26  * Intel(R) Ethernet Controller X540
27  * Intel(R) Ethernet Controller x550
28  * Intel(R) Ethernet Controller X552
29  * Intel(R) Ethernet Controller X553
30
31 For information on how to identify your adapter, and for the latest Intel
32 network drivers, refer to the Intel Support website:
33 https://www.intel.com/support
34
35 SFP+ Devices with Pluggable Optics
36 ----------------------------------
37
38 82599-BASED ADAPTERS
39 ~~~~~~~~~~~~~~~~~~~~
40 NOTES:
41 - If your 82599-based Intel(R) Network Adapter came with Intel optics or is an
42 Intel(R) Ethernet Server Adapter X520-2, then it only supports Intel optics
43 and/or the direct attach cables listed below.
44 - When 82599-based SFP+ devices are connected back to back, they should be set
45 to the same Speed setting via ethtool. Results may vary if you mix speed
46 settings.
47
48 +---------------+---------------------------------------+------------------+
49 | Supplier      | Type                                  | Part Numbers     |
50 +===============+=======================================+==================+
51 | SR Modules                                                               |
52 +---------------+---------------------------------------+------------------+
53 | Intel         | DUAL RATE 1G/10G SFP+ SR (bailed)     | FTLX8571D3BCV-IT |
54 +---------------+---------------------------------------+------------------+
55 | Intel         | DUAL RATE 1G/10G SFP+ SR (bailed)     | AFBR-703SDZ-IN2  |
56 +---------------+---------------------------------------+------------------+
57 | Intel         | DUAL RATE 1G/10G SFP+ SR (bailed)     | AFBR-703SDDZ-IN1 |
58 +---------------+---------------------------------------+------------------+
59 | LR Modules                                                               |
60 +---------------+---------------------------------------+------------------+
61 | Intel         | DUAL RATE 1G/10G SFP+ LR (bailed)     | FTLX1471D3BCV-IT |
62 +---------------+---------------------------------------+------------------+
63 | Intel         | DUAL RATE 1G/10G SFP+ LR (bailed)     | AFCT-701SDZ-IN2  |
64 +---------------+---------------------------------------+------------------+
65 | Intel         | DUAL RATE 1G/10G SFP+ LR (bailed)     | AFCT-701SDDZ-IN1 |
66 +---------------+---------------------------------------+------------------+
67
68 The following is a list of 3rd party SFP+ modules that have received some
69 testing. Not all modules are applicable to all devices.
70
71 +---------------+---------------------------------------+------------------+
72 | Supplier      | Type                                  | Part Numbers     |
73 +===============+=======================================+==================+
74 | Finisar       | SFP+ SR bailed, 10g single rate       | FTLX8571D3BCL    |
75 +---------------+---------------------------------------+------------------+
76 | Avago         | SFP+ SR bailed, 10g single rate       | AFBR-700SDZ      |
77 +---------------+---------------------------------------+------------------+
78 | Finisar       | SFP+ LR bailed, 10g single rate       | FTLX1471D3BCL    |
79 +---------------+---------------------------------------+------------------+
80 | Finisar       | DUAL RATE 1G/10G SFP+ SR (No Bail)    | FTLX8571D3QCV-IT |
81 +---------------+---------------------------------------+------------------+
82 | Avago         | DUAL RATE 1G/10G SFP+ SR (No Bail)    | AFBR-703SDZ-IN1  |
83 +---------------+---------------------------------------+------------------+
84 | Finisar       | DUAL RATE 1G/10G SFP+ LR (No Bail)    | FTLX1471D3QCV-IT |
85 +---------------+---------------------------------------+------------------+
86 | Avago         | DUAL RATE 1G/10G SFP+ LR (No Bail)    | AFCT-701SDZ-IN1  |
87 +---------------+---------------------------------------+------------------+
88 | Finisar       | 1000BASE-T SFP                        | FCLF8522P2BTL    |
89 +---------------+---------------------------------------+------------------+
90 | Avago         | 1000BASE-T                            | ABCU-5710RZ      |
91 +---------------+---------------------------------------+------------------+
92 | HP            | 1000BASE-SX SFP                       | 453153-001       |
93 +---------------+---------------------------------------+------------------+
94
95 82599-based adapters support all passive and active limiting direct attach
96 cables that comply with SFF-8431 v4.1 and SFF-8472 v10.4 specifications.
97
98 Laser turns off for SFP+ when ifconfig ethX down
99 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
100 "ifconfig ethX down" turns off the laser for 82599-based SFP+ fiber adapters.
101 "ifconfig ethX up" turns on the laser.
102 Alternatively, you can use "ip link set [down/up] dev ethX" to turn the
103 laser off and on.
104
105
106 82599-based QSFP+ Adapters
107 ~~~~~~~~~~~~~~~~~~~~~~~~~~
108 NOTES:
109 - If your 82599-based Intel(R) Network Adapter came with Intel optics, it only
110 supports Intel optics.
111 - 82599-based QSFP+ adapters only support 4x10 Gbps connections.  1x40 Gbps
112 connections are not supported. QSFP+ link partners must be configured for
113 4x10 Gbps.
114 - 82599-based QSFP+ adapters do not support automatic link speed detection.
115 The link speed must be configured to either 10 Gbps or 1 Gbps to match the link
116 partners speed capabilities. Incorrect speed configurations will result in
117 failure to link.
118 - Intel(R) Ethernet Converged Network Adapter X520-Q1 only supports the optics
119 and direct attach cables listed below.
120
121 +---------------+---------------------------------------+------------------+
122 | Supplier      | Type                                  | Part Numbers     |
123 +===============+=======================================+==================+
124 | Intel         | DUAL RATE 1G/10G QSFP+ SRL (bailed)   | E10GQSFPSR       |
125 +---------------+---------------------------------------+------------------+
126
127 82599-based QSFP+ adapters support all passive and active limiting QSFP+
128 direct attach cables that comply with SFF-8436 v4.1 specifications.
129
130 82598-BASED ADAPTERS
131 ~~~~~~~~~~~~~~~~~~~~
132 NOTES:
133 - Intel(r) Ethernet Network Adapters that support removable optical modules
134 only support their original module type (for example, the Intel(R) 10 Gigabit
135 SR Dual Port Express Module only supports SR optical modules). If you plug in
136 a different type of module, the driver will not load.
137 - Hot Swapping/hot plugging optical modules is not supported.
138 - Only single speed, 10 gigabit modules are supported.
139 - LAN on Motherboard (LOMs) may support DA, SR, or LR modules. Other module
140 types are not supported. Please see your system documentation for details.
141
142 The following is a list of SFP+ modules and direct attach cables that have
143 received some testing. Not all modules are applicable to all devices.
144
145 +---------------+---------------------------------------+------------------+
146 | Supplier      | Type                                  | Part Numbers     |
147 +===============+=======================================+==================+
148 | Finisar       | SFP+ SR bailed, 10g single rate       | FTLX8571D3BCL    |
149 +---------------+---------------------------------------+------------------+
150 | Avago         | SFP+ SR bailed, 10g single rate       | AFBR-700SDZ      |
151 +---------------+---------------------------------------+------------------+
152 | Finisar       | SFP+ LR bailed, 10g single rate       | FTLX1471D3BCL    |
153 +---------------+---------------------------------------+------------------+
154
155 82598-based adapters support all passive direct attach cables that comply with
156 SFF-8431 v4.1 and SFF-8472 v10.4 specifications. Active direct attach cables
157 are not supported.
158
159 Third party optic modules and cables referred to above are listed only for the
160 purpose of highlighting third party specifications and potential
161 compatibility, and are not recommendations or endorsements or sponsorship of
162 any third party's product by Intel. Intel is not endorsing or promoting
163 products made by any third party and the third party reference is provided
164 only to share information regarding certain optic modules and cables with the
165 above specifications. There may be other manufacturers or suppliers, producing
166 or supplying optic modules and cables with similar or matching descriptions.
167 Customers must use their own discretion and diligence to purchase optic
168 modules and cables from any third party of their choice. Customers are solely
169 responsible for assessing the suitability of the product and/or devices and
170 for the selection of the vendor for purchasing any product. THE OPTIC MODULES
171 AND CABLES REFERRED TO ABOVE ARE NOT WARRANTED OR SUPPORTED BY INTEL. INTEL
172 ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED
173 WARRANTY, RELATING TO SALE AND/OR USE OF SUCH THIRD PARTY PRODUCTS OR
174 SELECTION OF VENDOR BY CUSTOMERS.
175
176 Command Line Parameters
177 =======================
178
179 max_vfs
180 -------
181 :Valid Range: 1-63
182
183 This parameter adds support for SR-IOV. It causes the driver to spawn up to
184 max_vfs worth of virtual functions.
185 If the value is greater than 0 it will also force the VMDq parameter to be 1 or
186 more.
187
188 NOTE: This parameter is only used on kernel 3.7.x and below. On kernel 3.8.x
189 and above, use sysfs to enable VFs. Also, for Red Hat distributions, this
190 parameter is only used on version 6.6 and older. For version 6.7 and newer, use
191 sysfs. For example::
192
193   #echo $num_vf_enabled > /sys/class/net/$dev/device/sriov_numvfs // enable VFs
194   #echo 0 > /sys/class/net/$dev/device/sriov_numvfs               //disable VFs
195
196 The parameters for the driver are referenced by position. Thus, if you have a
197 dual port adapter, or more than one adapter in your system, and want N virtual
198 functions per port, you must specify a number for each port with each parameter
199 separated by a comma. For example::
200
201   modprobe ixgbe max_vfs=4
202
203 This will spawn 4 VFs on the first port.
204
205 ::
206
207   modprobe ixgbe max_vfs=2,4
208
209 This will spawn 2 VFs on the first port and 4 VFs on the second port.
210
211 NOTE: Caution must be used in loading the driver with these parameters.
212 Depending on your system configuration, number of slots, etc., it is impossible
213 to predict in all cases where the positions would be on the command line.
214
215 NOTE: Neither the device nor the driver control how VFs are mapped into config
216 space. Bus layout will vary by operating system. On operating systems that
217 support it, you can check sysfs to find the mapping.
218
219 NOTE: When either SR-IOV mode or VMDq mode is enabled, hardware VLAN filtering
220 and VLAN tag stripping/insertion will remain enabled. Please remove the old
221 VLAN filter before the new VLAN filter is added. For example,
222
223 ::
224
225   ip link set eth0 vf 0 vlan 100 // set VLAN 100 for VF 0
226   ip link set eth0 vf 0 vlan 0   // Delete VLAN 100
227   ip link set eth0 vf 0 vlan 200 // set a new VLAN 200 for VF 0
228
229 With kernel 3.6, the driver supports the simultaneous usage of max_vfs and DCB
230 features, subject to the constraints described below. Prior to kernel 3.6, the
231 driver did not support the simultaneous operation of max_vfs greater than 0 and
232 the DCB features (multiple traffic classes utilizing Priority Flow Control and
233 Extended Transmission Selection).
234
235 When DCB is enabled, network traffic is transmitted and received through
236 multiple traffic classes (packet buffers in the NIC). The traffic is associated
237 with a specific class based on priority, which has a value of 0 through 7 used
238 in the VLAN tag. When SR-IOV is not enabled, each traffic class is associated
239 with a set of receive/transmit descriptor queue pairs. The number of queue
240 pairs for a given traffic class depends on the hardware configuration. When
241 SR-IOV is enabled, the descriptor queue pairs are grouped into pools. The
242 Physical Function (PF) and each Virtual Function (VF) is allocated a pool of
243 receive/transmit descriptor queue pairs. When multiple traffic classes are
244 configured (for example, DCB is enabled), each pool contains a queue pair from
245 each traffic class. When a single traffic class is configured in the hardware,
246 the pools contain multiple queue pairs from the single traffic class.
247
248 The number of VFs that can be allocated depends on the number of traffic
249 classes that can be enabled. The configurable number of traffic classes for
250 each enabled VF is as follows:
251 0 - 15 VFs = Up to 8 traffic classes, depending on device support
252 16 - 31 VFs = Up to 4 traffic classes
253 32 - 63 VFs = 1 traffic class
254
255 When VFs are configured, the PF is allocated one pool as well. The PF supports
256 the DCB features with the constraint that each traffic class will only use a
257 single queue pair. When zero VFs are configured, the PF can support multiple
258 queue pairs per traffic class.
259
260 allow_unsupported_sfp
261 ---------------------
262 :Valid Range: 0,1
263 :Default Value: 0 (disabled)
264
265 This parameter allows unsupported and untested SFP+ modules on 82599-based
266 adapters, as long as the type of module is known to the driver.
267
268 debug
269 -----
270 :Valid Range: 0-16 (0=none,...,16=all)
271 :Default Value: 0
272
273 This parameter adjusts the level of debug messages displayed in the system
274 logs.
275
276
277 Additional Features and Configurations
278 ======================================
279
280 Flow Control
281 ------------
282 Ethernet Flow Control (IEEE 802.3x) can be configured with ethtool to enable
283 receiving and transmitting pause frames for ixgbe. When transmit is enabled,
284 pause frames are generated when the receive packet buffer crosses a predefined
285 threshold. When receive is enabled, the transmit unit will halt for the time
286 delay specified when a pause frame is received.
287
288 NOTE: You must have a flow control capable link partner.
289
290 Flow Control is enabled by default.
291
292 Use ethtool to change the flow control settings. To enable or disable Rx or
293 Tx Flow Control::
294
295   ethtool -A eth? rx <on|off> tx <on|off>
296
297 Note: This command only enables or disables Flow Control if auto-negotiation is
298 disabled. If auto-negotiation is enabled, this command changes the parameters
299 used for auto-negotiation with the link partner.
300
301 To enable or disable auto-negotiation::
302
303   ethtool -s eth? autoneg <on|off>
304
305 Note: Flow Control auto-negotiation is part of link auto-negotiation. Depending
306 on your device, you may not be able to change the auto-negotiation setting.
307
308 NOTE: For 82598 backplane cards entering 1 gigabit mode, flow control default
309 behavior is changed to off. Flow control in 1 gigabit mode on these devices can
310 lead to transmit hangs.
311
312 Intel(R) Ethernet Flow Director
313 -------------------------------
314 The Intel Ethernet Flow Director performs the following tasks:
315
316 - Directs receive packets according to their flows to different queues.
317 - Enables tight control on routing a flow in the platform.
318 - Matches flows and CPU cores for flow affinity.
319 - Supports multiple parameters for flexible flow classification and load
320   balancing (in SFP mode only).
321
322 NOTE: Intel Ethernet Flow Director masking works in the opposite manner from
323 subnet masking. In the following command::
324
325   #ethtool -N eth11 flow-type ip4 src-ip 172.4.1.2 m 255.0.0.0 dst-ip \
326   172.21.1.1 m 255.128.0.0 action 31
327
328 The src-ip value that is written to the filter will be 0.4.1.2, not 172.0.0.0
329 as might be expected. Similarly, the dst-ip value written to the filter will be
330 0.21.1.1, not 172.0.0.0.
331
332 To enable or disable the Intel Ethernet Flow Director::
333
334   # ethtool -K ethX ntuple <on|off>
335
336 When disabling ntuple filters, all the user programmed filters are flushed from
337 the driver cache and hardware. All needed filters must be re-added when ntuple
338 is re-enabled.
339
340 To add a filter that directs packet to queue 2, use -U or -N switch::
341
342   # ethtool -N ethX flow-type tcp4 src-ip 192.168.10.1 dst-ip \
343   192.168.10.2 src-port 2000 dst-port 2001 action 2 [loc 1]
344
345 To see the list of filters currently present::
346
347   # ethtool <-u|-n> ethX
348
349 Sideband Perfect Filters
350 ------------------------
351 Sideband Perfect Filters are used to direct traffic that matches specified
352 characteristics. They are enabled through ethtool's ntuple interface. To add a
353 new filter use the following command::
354
355   ethtool -U <device> flow-type <type> src-ip <ip> dst-ip <ip> src-port <port> \
356   dst-port <port> action <queue>
357
358 Where:
359   <device> - the ethernet device to program
360   <type> - can be ip4, tcp4, udp4, or sctp4
361   <ip> - the IP address to match on
362   <port> - the port number to match on
363   <queue> - the queue to direct traffic towards (-1 discards the matched traffic)
364
365 Use the following command to delete a filter::
366
367   ethtool -U <device> delete <N>
368
369 Where <N> is the filter id displayed when printing all the active filters, and
370 may also have been specified using "loc <N>" when adding the filter.
371
372 The following example matches TCP traffic sent from 192.168.0.1, port 5300,
373 directed to 192.168.0.5, port 80, and sends it to queue 7::
374
375   ethtool -U enp130s0 flow-type tcp4 src-ip 192.168.0.1 dst-ip 192.168.0.5 \
376   src-port 5300 dst-port 80 action 7
377
378 For each flow-type, the programmed filters must all have the same matching
379 input set. For example, issuing the following two commands is acceptable::
380
381   ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7
382   ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.5 src-port 55 action 10
383
384 Issuing the next two commands, however, is not acceptable, since the first
385 specifies src-ip and the second specifies dst-ip::
386
387   ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7
388   ethtool -U enp130s0 flow-type ip4 dst-ip 192.168.0.5 src-port 55 action 10
389
390 The second command will fail with an error. You may program multiple filters
391 with the same fields, using different values, but, on one device, you may not
392 program two TCP4 filters with different matching fields.
393
394 Matching on a sub-portion of a field is not supported by the ixgbe driver, thus
395 partial mask fields are not supported.
396
397 To create filters that direct traffic to a specific Virtual Function, use the
398 "user-def" parameter. Specify the user-def as a 64 bit value, where the lower 32
399 bits represents the queue number, while the next 8 bits represent which VF.
400 Note that 0 is the PF, so the VF identifier is offset by 1. For example::
401
402   ... user-def 0x800000002 ...
403
404 specifies to direct traffic to Virtual Function 7 (8 minus 1) into queue 2 of
405 that VF.
406
407 Note that these filters will not break internal routing rules, and will not
408 route traffic that otherwise would not have been sent to the specified Virtual
409 Function.
410
411 Jumbo Frames
412 ------------
413 Jumbo Frames support is enabled by changing the Maximum Transmission Unit (MTU)
414 to a value larger than the default value of 1500.
415
416 Use the ifconfig command to increase the MTU size. For example, enter the
417 following where <x> is the interface number::
418
419   ifconfig eth<x> mtu 9000 up
420
421 Alternatively, you can use the ip command as follows::
422
423   ip link set mtu 9000 dev eth<x>
424   ip link set up dev eth<x>
425
426 This setting is not saved across reboots. The setting change can be made
427 permanent by adding 'MTU=9000' to the file::
428
429   /etc/sysconfig/network-scripts/ifcfg-eth<x> // for RHEL
430   /etc/sysconfig/network/<config_file> // for SLES
431
432 NOTE: The maximum MTU setting for Jumbo Frames is 9710. This value coincides
433 with the maximum Jumbo Frames size of 9728 bytes.
434
435 NOTE: This driver will attempt to use multiple page sized buffers to receive
436 each jumbo packet. This should help to avoid buffer starvation issues when
437 allocating receive packets.
438
439 NOTE: For 82599-based network connections, if you are enabling jumbo frames in
440 a virtual function (VF), jumbo frames must first be enabled in the physical
441 function (PF). The VF MTU setting cannot be larger than the PF MTU.
442
443 Generic Receive Offload, aka GRO
444 --------------------------------
445 The driver supports the in-kernel software implementation of GRO. GRO has
446 shown that by coalescing Rx traffic into larger chunks of data, CPU
447 utilization can be significantly reduced when under large Rx load. GRO is an
448 evolution of the previously-used LRO interface. GRO is able to coalesce
449 other protocols besides TCP. It's also safe to use with configurations that
450 are problematic for LRO, namely bridging and iSCSI.
451
452 Data Center Bridging (DCB)
453 --------------------------
454 NOTE:
455 The kernel assumes that TC0 is available, and will disable Priority Flow
456 Control (PFC) on the device if TC0 is not available. To fix this, ensure TC0 is
457 enabled when setting up DCB on your switch.
458
459 DCB is a configuration Quality of Service implementation in hardware. It uses
460 the VLAN priority tag (802.1p) to filter traffic. That means that there are 8
461 different priorities that traffic can be filtered into. It also enables
462 priority flow control (802.1Qbb) which can limit or eliminate the number of
463 dropped packets during network stress. Bandwidth can be allocated to each of
464 these priorities, which is enforced at the hardware level (802.1Qaz).
465
466 Adapter firmware implements LLDP and DCBX protocol agents as per 802.1AB and
467 802.1Qaz respectively. The firmware based DCBX agent runs in willing mode only
468 and can accept settings from a DCBX capable peer. Software configuration of
469 DCBX parameters via dcbtool/lldptool are not supported.
470
471 The ixgbe driver implements the DCB netlink interface layer to allow user-space
472 to communicate with the driver and query DCB configuration for the port.
473
474 ethtool
475 -------
476 The driver utilizes the ethtool interface for driver configuration and
477 diagnostics, as well as displaying statistical information. The latest ethtool
478 version is required for this functionality. Download it at:
479 https://www.kernel.org/pub/software/network/ethtool/
480
481 FCoE
482 ----
483 The ixgbe driver supports Fiber Channel over Ethernet (FCoE) and Data Center
484 Bridging (DCB). This code has no default effect on the regular driver
485 operation. Configuring DCB and FCoE is outside the scope of this README. Refer
486 to http://www.open-fcoe.org/ for FCoE project information and contact
487 ixgbe-eedc@lists.sourceforge.net for DCB information.
488
489 MAC and VLAN anti-spoofing feature
490 ----------------------------------
491 When a malicious driver attempts to send a spoofed packet, it is dropped by the
492 hardware and not transmitted.
493
494 An interrupt is sent to the PF driver notifying it of the spoof attempt. When a
495 spoofed packet is detected, the PF driver will send the following message to
496 the system log (displayed by the "dmesg" command)::
497
498   ixgbe ethX: ixgbe_spoof_check: n spoofed packets detected
499
500 where "x" is the PF interface number; and "n" is number of spoofed packets.
501 NOTE: This feature can be disabled for a specific Virtual Function (VF)::
502
503   ip link set <pf dev> vf <vf id> spoofchk {off|on}
504
505 IPsec Offload
506 -------------
507 The ixgbe driver supports IPsec Hardware Offload.  When creating Security
508 Associations with "ip xfrm ..." the 'offload' tag option can be used to
509 register the IPsec SA with the driver in order to get higher throughput in
510 the secure communications.
511
512 The offload is also supported for ixgbe's VFs, but the VF must be set as
513 'trusted' and the support must be enabled with::
514
515   ethtool --set-priv-flags eth<x> vf-ipsec on
516   ip link set eth<x> vf <y> trust on
517
518
519 Known Issues/Troubleshooting
520 ============================
521
522 Enabling SR-IOV in a 64-bit Microsoft* Windows Server* 2012/R2 guest OS
523 -----------------------------------------------------------------------
524 Linux KVM Hypervisor/VMM supports direct assignment of a PCIe device to a VM.
525 This includes traditional PCIe devices, as well as SR-IOV-capable devices based
526 on the Intel Ethernet Controller XL710.
527
528
529 Support
530 =======
531 For general information, go to the Intel support website at:
532
533 https://www.intel.com/support/
534
535 or the Intel Wired Networking project hosted by Sourceforge at:
536
537 https://sourceforge.net/projects/e1000
538
539 If an issue is identified with the released source code on a supported kernel
540 with a supported adapter, email the specific information related to the issue
541 to e1000-devel@lists.sf.net.