1 ASPEED AST2400/AST2500 PWM and Fan Tacho controller device driver
2
3 The ASPEED PWM controller can support upto 8 PWM outputs. The ASPEED Fan Tacho
4 controller can support upto 16 Fan tachometer inputs.
5
6 There can be upto 8 fans supported. Each fan can have one PWM output and
7 one/two Fan tach inputs.
8
9 Required properties for pwm-tacho node:
10 - #address-cells : should be 1.
11
12 - #size-cells : should be 1.
13
14 - #cooling-cells: should be 2.
15
16 - reg : address and length of the register set for the device.
17
18 - pinctrl-names : a pinctrl state named "default" must be defined.
19
20 - pinctrl-0 : phandle referencing pin configuration of the PWM ports.
21
22 - compatible : should be "aspeed,ast2400-pwm-tacho" for AST2400 and
23                "aspeed,ast2500-pwm-tacho" for AST2500.
24
25 - clocks : phandle to clock provider with the clock number in the second cell
26
27 - resets : phandle to reset controller with the reset number in the second cell
28
29 fan subnode format:
30 ===================
31 Under fan subnode there can upto 8 child nodes, with each child node
32 representing a fan. If there are 8 fans each fan can have one PWM port and
33 one/two Fan tach inputs.
34 For PWM port can be configured cooling-levels to create cooling device.
35 Cooling device could be bound to a thermal zone for the thermal control.
36
37 Required properties for each child node:
38 - reg : should specify PWM source port.
39         integer value in the range 0 to 7 with 0 indicating PWM port A and
40         7 indicating PWM port H.
41
42 - cooling-levels: PWM duty cycle values in a range from 0 to 255
43                   which correspond to thermal cooling states.
44
45 - aspeed,fan-tach-ch : should specify the Fan tach input channel.
46                 integer value in the range 0 through 15, with 0 indicating
47                 Fan tach channel 0 and 15 indicating Fan tach channel 15.
48                 Atleast one Fan tach input channel is required.
49
50 Examples:
51
52 pwm_tacho: pwmtachocontroller@1e786000 {
53         #address-cells = <1>;
54         #size-cells = <1>;
55         #cooling-cells = <2>;
56         reg = <0x1E786000 0x1000>;
57         compatible = "aspeed,ast2500-pwm-tacho";
58         clocks = <&syscon ASPEED_CLK_APB>;
59         resets = <&syscon ASPEED_RESET_PWM>;
60         pinctrl-names = "default";
61         pinctrl-0 = <&pinctrl_pwm0_default &pinctrl_pwm1_default>;
62
63         fan@0 {
64                 reg = <0x00>;
65                 cooling-levels = /bits/ 8 <125 151 177 203 229 255>;
66                 aspeed,fan-tach-ch = /bits/ 8 <0x00>;
67         };
68
69         fan@1 {
70                 reg = <0x01>;
71                 aspeed,fan-tach-ch = /bits/ 8 <0x01 0x02>;
72         };
73 };