Merge tag 'for-v3.18-rc' of git://git.infradead.org/battery-2.6
authorLinus Torvalds <torvalds@linux-foundation.org>
Sat, 15 Nov 2014 23:22:51 +0000 (15:22 -0800)
committerLinus Torvalds <torvalds@linux-foundation.org>
Sat, 15 Nov 2014 23:22:51 +0000 (15:22 -0800)
Pull power supply updates from Sebastian Reichel:
 "Power supply and reset changes for the v3.18-rc:

   - misc. charger-manager fixes
   - year 2038 fix in ab8500_fg
   - fix error handling of bq2415x_charger"

* tag 'for-v3.18-rc' of git://git.infradead.org/battery-2.6:
  power: charger-manager: Fix accessing invalidated power supply after charger unbind
  power: charger-manager: Fix accessing invalidated power supply after fuel gauge unbind
  power: charger-manager: Avoid recursive thermal get_temp call
  power_supply: Add no_thermal property to prevent recursive get_temp calls
  power: bq2415x_charger: Fix memory leak on DTS parsing error
  power: bq2415x_charger: Properly handle ENODEV from power_supply_get_by_phandle
  power: ab8500_fg.c: use 64-bit time types

drivers/power/ab8500_fg.c
drivers/power/bq2415x_charger.c
drivers/power/charger-manager.c
drivers/power/power_supply_core.c
include/linux/power/charger-manager.h
include/linux/power_supply.h

index 217da4b2ca8639ee5f2d5ced62615bfc558aed4f..99a78d365ceb11f2c3c6308296f62ce4db6c2a5d 100644 (file)
@@ -25,6 +25,7 @@
 #include <linux/slab.h>
 #include <linux/delay.h>
 #include <linux/time.h>
+#include <linux/time64.h>
 #include <linux/of.h>
 #include <linux/completion.h>
 #include <linux/mfd/core.h>
@@ -108,7 +109,7 @@ enum ab8500_fg_calibration_state {
 struct ab8500_fg_avg_cap {
        int avg;
        int samples[NBR_AVG_SAMPLES];
-       __kernel_time_t time_stamps[NBR_AVG_SAMPLES];
+       time64_t time_stamps[NBR_AVG_SAMPLES];
        int pos;
        int nbr_samples;
        int sum;
@@ -386,15 +387,15 @@ static int ab8500_fg_is_low_curr(struct ab8500_fg *di, int curr)
  */
 static int ab8500_fg_add_cap_sample(struct ab8500_fg *di, int sample)
 {
-       struct timespec ts;
+       struct timespec64 ts64;
        struct ab8500_fg_avg_cap *avg = &di->avg_cap;
 
-       getnstimeofday(&ts);
+       getnstimeofday64(&ts64);
 
        do {
                avg->sum += sample - avg->samples[avg->pos];
                avg->samples[avg->pos] = sample;
-               avg->time_stamps[avg->pos] = ts.tv_sec;
+               avg->time_stamps[avg->pos] = ts64.tv_sec;
                avg->pos++;
 
                if (avg->pos == NBR_AVG_SAMPLES)
@@ -407,7 +408,7 @@ static int ab8500_fg_add_cap_sample(struct ab8500_fg *di, int sample)
                 * Check the time stamp for each sample. If too old,
                 * replace with latest sample
                 */
-       } while (ts.tv_sec - VALID_CAPACITY_SEC > avg->time_stamps[avg->pos]);
+       } while (ts64.tv_sec - VALID_CAPACITY_SEC > avg->time_stamps[avg->pos]);
 
        avg->avg = avg->sum / avg->nbr_samples;
 
@@ -446,14 +447,14 @@ static void ab8500_fg_clear_cap_samples(struct ab8500_fg *di)
 static void ab8500_fg_fill_cap_sample(struct ab8500_fg *di, int sample)
 {
        int i;
-       struct timespec ts;
+       struct timespec64 ts64;
        struct ab8500_fg_avg_cap *avg = &di->avg_cap;
 
-       getnstimeofday(&ts);
+       getnstimeofday64(&ts64);
 
        for (i = 0; i < NBR_AVG_SAMPLES; i++) {
                avg->samples[i] = sample;
-               avg->time_stamps[i] = ts.tv_sec;
+               avg->time_stamps[i] = ts64.tv_sec;
        }
 
        avg->pos = 0;
index e384844a1ae1957ffd3687e7f54d0ff3eba2b59f..1f49986fc6057c8c4db858735ec8d9fd38326f8a 100644 (file)
@@ -1579,8 +1579,15 @@ static int bq2415x_probe(struct i2c_client *client,
        if (np) {
                bq->notify_psy = power_supply_get_by_phandle(np, "ti,usb-charger-detection");
 
-               if (!bq->notify_psy)
-                       return -EPROBE_DEFER;
+               if (IS_ERR(bq->notify_psy)) {
+                       dev_info(&client->dev,
+                               "no 'ti,usb-charger-detection' property (err=%ld)\n",
+                               PTR_ERR(bq->notify_psy));
+                       bq->notify_psy = NULL;
+               } else if (!bq->notify_psy) {
+                       ret = -EPROBE_DEFER;
+                       goto error_2;
+               }
        }
        else if (pdata->notify_device)
                bq->notify_psy = power_supply_get_by_name(pdata->notify_device);
@@ -1602,27 +1609,27 @@ static int bq2415x_probe(struct i2c_client *client,
                ret = of_property_read_u32(np, "ti,current-limit",
                                &bq->init_data.current_limit);
                if (ret)
-                       return ret;
+                       goto error_2;
                ret = of_property_read_u32(np, "ti,weak-battery-voltage",
                                &bq->init_data.weak_battery_voltage);
                if (ret)
-                       return ret;
+                       goto error_2;
                ret = of_property_read_u32(np, "ti,battery-regulation-voltage",
                                &bq->init_data.battery_regulation_voltage);
                if (ret)
-                       return ret;
+                       goto error_2;
                ret = of_property_read_u32(np, "ti,charge-current",
                                &bq->init_data.charge_current);
                if (ret)
-                       return ret;
+                       goto error_2;
                ret = of_property_read_u32(np, "ti,termination-current",
                                &bq->init_data.termination_current);
                if (ret)
-                       return ret;
+                       goto error_2;
                ret = of_property_read_u32(np, "ti,resistor-sense",
                                &bq->init_data.resistor_sense);
                if (ret)
-                       return ret;
+                       goto error_2;
        } else {
                memcpy(&bq->init_data, pdata, sizeof(bq->init_data));
        }
index 7098a1ce2d3c1068e2ef6cc5fbbe4d185ece9850..ef8094a61f1e91caa16fdcb204ce4ced9485334e 100644 (file)
@@ -97,6 +97,7 @@ static struct charger_global_desc *g_desc; /* init with setup_charger_manager */
 static bool is_batt_present(struct charger_manager *cm)
 {
        union power_supply_propval val;
+       struct power_supply *psy;
        bool present = false;
        int i, ret;
 
@@ -107,16 +108,27 @@ static bool is_batt_present(struct charger_manager *cm)
        case CM_NO_BATTERY:
                break;
        case CM_FUEL_GAUGE:
-               ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+               psy = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+               if (!psy)
+                       break;
+
+               ret = psy->get_property(psy,
                                POWER_SUPPLY_PROP_PRESENT, &val);
                if (ret == 0 && val.intval)
                        present = true;
                break;
        case CM_CHARGER_STAT:
-               for (i = 0; cm->charger_stat[i]; i++) {
-                       ret = cm->charger_stat[i]->get_property(
-                                       cm->charger_stat[i],
-                                       POWER_SUPPLY_PROP_PRESENT, &val);
+               for (i = 0; cm->desc->psy_charger_stat[i]; i++) {
+                       psy = power_supply_get_by_name(
+                                       cm->desc->psy_charger_stat[i]);
+                       if (!psy) {
+                               dev_err(cm->dev, "Cannot find power supply \"%s\"\n",
+                                       cm->desc->psy_charger_stat[i]);
+                               continue;
+                       }
+
+                       ret = psy->get_property(psy, POWER_SUPPLY_PROP_PRESENT,
+                                       &val);
                        if (ret == 0 && val.intval) {
                                present = true;
                                break;
@@ -139,14 +151,20 @@ static bool is_batt_present(struct charger_manager *cm)
 static bool is_ext_pwr_online(struct charger_manager *cm)
 {
        union power_supply_propval val;
+       struct power_supply *psy;
        bool online = false;
        int i, ret;
 
        /* If at least one of them has one, it's yes. */
-       for (i = 0; cm->charger_stat[i]; i++) {
-               ret = cm->charger_stat[i]->get_property(
-                               cm->charger_stat[i],
-                               POWER_SUPPLY_PROP_ONLINE, &val);
+       for (i = 0; cm->desc->psy_charger_stat[i]; i++) {
+               psy = power_supply_get_by_name(cm->desc->psy_charger_stat[i]);
+               if (!psy) {
+                       dev_err(cm->dev, "Cannot find power supply \"%s\"\n",
+                                       cm->desc->psy_charger_stat[i]);
+                       continue;
+               }
+
+               ret = psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &val);
                if (ret == 0 && val.intval) {
                        online = true;
                        break;
@@ -167,12 +185,14 @@ static bool is_ext_pwr_online(struct charger_manager *cm)
 static int get_batt_uV(struct charger_manager *cm, int *uV)
 {
        union power_supply_propval val;
+       struct power_supply *fuel_gauge;
        int ret;
 
-       if (!cm->fuel_gauge)
+       fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+       if (!fuel_gauge)
                return -ENODEV;
 
-       ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+       ret = fuel_gauge->get_property(fuel_gauge,
                                POWER_SUPPLY_PROP_VOLTAGE_NOW, &val);
        if (ret)
                return ret;
@@ -189,6 +209,7 @@ static bool is_charging(struct charger_manager *cm)
 {
        int i, ret;
        bool charging = false;
+       struct power_supply *psy;
        union power_supply_propval val;
 
        /* If there is no battery, it cannot be charged */
@@ -196,17 +217,22 @@ static bool is_charging(struct charger_manager *cm)
                return false;
 
        /* If at least one of the charger is charging, return yes */
-       for (i = 0; cm->charger_stat[i]; i++) {
+       for (i = 0; cm->desc->psy_charger_stat[i]; i++) {
                /* 1. The charger sholuld not be DISABLED */
                if (cm->emergency_stop)
                        continue;
                if (!cm->charger_enabled)
                        continue;
 
+               psy = power_supply_get_by_name(cm->desc->psy_charger_stat[i]);
+               if (!psy) {
+                       dev_err(cm->dev, "Cannot find power supply \"%s\"\n",
+                                       cm->desc->psy_charger_stat[i]);
+                       continue;
+               }
+
                /* 2. The charger should be online (ext-power) */
-               ret = cm->charger_stat[i]->get_property(
-                               cm->charger_stat[i],
-                               POWER_SUPPLY_PROP_ONLINE, &val);
+               ret = psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &val);
                if (ret) {
                        dev_warn(cm->dev, "Cannot read ONLINE value from %s\n",
                                 cm->desc->psy_charger_stat[i]);
@@ -219,9 +245,7 @@ static bool is_charging(struct charger_manager *cm)
                 * 3. The charger should not be FULL, DISCHARGING,
                 * or NOT_CHARGING.
                 */
-               ret = cm->charger_stat[i]->get_property(
-                               cm->charger_stat[i],
-                               POWER_SUPPLY_PROP_STATUS, &val);
+               ret = psy->get_property(psy, POWER_SUPPLY_PROP_STATUS, &val);
                if (ret) {
                        dev_warn(cm->dev, "Cannot read STATUS value from %s\n",
                                 cm->desc->psy_charger_stat[i]);
@@ -248,6 +272,7 @@ static bool is_full_charged(struct charger_manager *cm)
 {
        struct charger_desc *desc = cm->desc;
        union power_supply_propval val;
+       struct power_supply *fuel_gauge;
        int ret = 0;
        int uV;
 
@@ -255,11 +280,15 @@ static bool is_full_charged(struct charger_manager *cm)
        if (!is_batt_present(cm))
                return false;
 
-       if (cm->fuel_gauge && desc->fullbatt_full_capacity > 0) {
+       fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+       if (!fuel_gauge)
+               return false;
+
+       if (desc->fullbatt_full_capacity > 0) {
                val.intval = 0;
 
                /* Not full if capacity of fuel gauge isn't full */
-               ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+               ret = fuel_gauge->get_property(fuel_gauge,
                                POWER_SUPPLY_PROP_CHARGE_FULL, &val);
                if (!ret && val.intval > desc->fullbatt_full_capacity)
                        return true;
@@ -273,10 +302,10 @@ static bool is_full_charged(struct charger_manager *cm)
        }
 
        /* Full, if the capacity is more than fullbatt_soc */
-       if (cm->fuel_gauge && desc->fullbatt_soc > 0) {
+       if (desc->fullbatt_soc > 0) {
                val.intval = 0;
 
-               ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+               ret = fuel_gauge->get_property(fuel_gauge,
                                POWER_SUPPLY_PROP_CAPACITY, &val);
                if (!ret && val.intval >= desc->fullbatt_soc)
                        return true;
@@ -551,6 +580,20 @@ static int check_charging_duration(struct charger_manager *cm)
        return ret;
 }
 
+static int cm_get_battery_temperature_by_psy(struct charger_manager *cm,
+                                       int *temp)
+{
+       struct power_supply *fuel_gauge;
+
+       fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+       if (!fuel_gauge)
+               return -ENODEV;
+
+       return fuel_gauge->get_property(fuel_gauge,
+                               POWER_SUPPLY_PROP_TEMP,
+                               (union power_supply_propval *)temp);
+}
+
 static int cm_get_battery_temperature(struct charger_manager *cm,
                                        int *temp)
 {
@@ -560,15 +603,18 @@ static int cm_get_battery_temperature(struct charger_manager *cm,
                return -ENODEV;
 
 #ifdef CONFIG_THERMAL
-       ret = thermal_zone_get_temp(cm->tzd_batt, (unsigned long *)temp);
-       if (!ret)
-               /* Calibrate temperature unit */
-               *temp /= 100;
-#else
-       ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
-                               POWER_SUPPLY_PROP_TEMP,
-                               (union power_supply_propval *)temp);
+       if (cm->tzd_batt) {
+               ret = thermal_zone_get_temp(cm->tzd_batt, (unsigned long *)temp);
+               if (!ret)
+                       /* Calibrate temperature unit */
+                       *temp /= 100;
+       } else
 #endif
+       {
+               /* if-else continued from CONFIG_THERMAL */
+               ret = cm_get_battery_temperature_by_psy(cm, temp);
+       }
+
        return ret;
 }
 
@@ -827,6 +873,7 @@ static int charger_get_property(struct power_supply *psy,
        struct charger_manager *cm = container_of(psy,
                        struct charger_manager, charger_psy);
        struct charger_desc *desc = cm->desc;
+       struct power_supply *fuel_gauge;
        int ret = 0;
        int uV;
 
@@ -857,14 +904,20 @@ static int charger_get_property(struct power_supply *psy,
                ret = get_batt_uV(cm, &val->intval);
                break;
        case POWER_SUPPLY_PROP_CURRENT_NOW:
-               ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+               fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+               if (!fuel_gauge) {
+                       ret = -ENODEV;
+                       break;
+               }
+               ret = fuel_gauge->get_property(fuel_gauge,
                                POWER_SUPPLY_PROP_CURRENT_NOW, val);
                break;
        case POWER_SUPPLY_PROP_TEMP:
        case POWER_SUPPLY_PROP_TEMP_AMBIENT:
                return cm_get_battery_temperature(cm, &val->intval);
        case POWER_SUPPLY_PROP_CAPACITY:
-               if (!cm->fuel_gauge) {
+               fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+               if (!fuel_gauge) {
                        ret = -ENODEV;
                        break;
                }
@@ -875,7 +928,7 @@ static int charger_get_property(struct power_supply *psy,
                        break;
                }
 
-               ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+               ret = fuel_gauge->get_property(fuel_gauge,
                                        POWER_SUPPLY_PROP_CAPACITY, val);
                if (ret)
                        break;
@@ -924,7 +977,14 @@ static int charger_get_property(struct power_supply *psy,
                break;
        case POWER_SUPPLY_PROP_CHARGE_NOW:
                if (is_charging(cm)) {
-                       ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+                       fuel_gauge = power_supply_get_by_name(
+                                       cm->desc->psy_fuel_gauge);
+                       if (!fuel_gauge) {
+                               ret = -ENODEV;
+                               break;
+                       }
+
+                       ret = fuel_gauge->get_property(fuel_gauge,
                                                POWER_SUPPLY_PROP_CHARGE_NOW,
                                                val);
                        if (ret) {
@@ -970,6 +1030,7 @@ static struct power_supply psy_default = {
        .properties = default_charger_props,
        .num_properties = ARRAY_SIZE(default_charger_props),
        .get_property = charger_get_property,
+       .no_thermal = true,
 };
 
 /**
@@ -1485,14 +1546,15 @@ err:
        return ret;
 }
 
-static int cm_init_thermal_data(struct charger_manager *cm)
+static int cm_init_thermal_data(struct charger_manager *cm,
+               struct power_supply *fuel_gauge)
 {
        struct charger_desc *desc = cm->desc;
        union power_supply_propval val;
        int ret;
 
        /* Verify whether fuel gauge provides battery temperature */
-       ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+       ret = fuel_gauge->get_property(fuel_gauge,
                                        POWER_SUPPLY_PROP_TEMP, &val);
 
        if (!ret) {
@@ -1502,8 +1564,6 @@ static int cm_init_thermal_data(struct charger_manager *cm)
                cm->desc->measure_battery_temp = true;
        }
 #ifdef CONFIG_THERMAL
-       cm->tzd_batt = cm->fuel_gauge->tzd;
-
        if (ret && desc->thermal_zone) {
                cm->tzd_batt =
                        thermal_zone_get_zone_by_name(desc->thermal_zone);
@@ -1666,6 +1726,7 @@ static int charger_manager_probe(struct platform_device *pdev)
        int ret = 0, i = 0;
        int j = 0;
        union power_supply_propval val;
+       struct power_supply *fuel_gauge;
 
        if (g_desc && !rtc_dev && g_desc->rtc_name) {
                rtc_dev = rtc_class_open(g_desc->rtc_name);
@@ -1729,23 +1790,20 @@ static int charger_manager_probe(struct platform_device *pdev)
        while (desc->psy_charger_stat[i])
                i++;
 
-       cm->charger_stat = devm_kzalloc(&pdev->dev,
-                               sizeof(struct power_supply *) * i, GFP_KERNEL);
-       if (!cm->charger_stat)
-               return -ENOMEM;
-
+       /* Check if charger's supplies are present at probe */
        for (i = 0; desc->psy_charger_stat[i]; i++) {
-               cm->charger_stat[i] = power_supply_get_by_name(
-                                       desc->psy_charger_stat[i]);
-               if (!cm->charger_stat[i]) {
+               struct power_supply *psy;
+
+               psy = power_supply_get_by_name(desc->psy_charger_stat[i]);
+               if (!psy) {
                        dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n",
                                desc->psy_charger_stat[i]);
                        return -ENODEV;
                }
        }
 
-       cm->fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge);
-       if (!cm->fuel_gauge) {
+       fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge);
+       if (!fuel_gauge) {
                dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n",
                        desc->psy_fuel_gauge);
                return -ENODEV;
@@ -1788,13 +1846,13 @@ static int charger_manager_probe(struct platform_device *pdev)
        cm->charger_psy.num_properties = psy_default.num_properties;
 
        /* Find which optional psy-properties are available */
-       if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
+       if (!fuel_gauge->get_property(fuel_gauge,
                                          POWER_SUPPLY_PROP_CHARGE_NOW, &val)) {
                cm->charger_psy.properties[cm->charger_psy.num_properties] =
                                POWER_SUPPLY_PROP_CHARGE_NOW;
                cm->charger_psy.num_properties++;
        }
-       if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
+       if (!fuel_gauge->get_property(fuel_gauge,
                                          POWER_SUPPLY_PROP_CURRENT_NOW,
                                          &val)) {
                cm->charger_psy.properties[cm->charger_psy.num_properties] =
@@ -1802,7 +1860,7 @@ static int charger_manager_probe(struct platform_device *pdev)
                cm->charger_psy.num_properties++;
        }
 
-       ret = cm_init_thermal_data(cm);
+       ret = cm_init_thermal_data(cm, fuel_gauge);
        if (ret) {
                dev_err(&pdev->dev, "Failed to initialize thermal data\n");
                cm->desc->measure_battery_temp = false;
@@ -2066,8 +2124,8 @@ static bool find_power_supply(struct charger_manager *cm,
        int i;
        bool found = false;
 
-       for (i = 0; cm->charger_stat[i]; i++) {
-               if (psy == cm->charger_stat[i]) {
+       for (i = 0; cm->desc->psy_charger_stat[i]; i++) {
+               if (!strcmp(psy->name, cm->desc->psy_charger_stat[i])) {
                        found = true;
                        break;
                }
index 6cb7fe5c022d48ca237e31eb89e78f8f70665776..694e8cddd5c13e1760e7c9cd5fc0170876a9df04 100644 (file)
@@ -417,6 +417,9 @@ static int psy_register_thermal(struct power_supply *psy)
 {
        int i;
 
+       if (psy->no_thermal)
+               return 0;
+
        /* Register battery zone device psy reports temperature */
        for (i = 0; i < psy->num_properties; i++) {
                if (psy->properties[i] == POWER_SUPPLY_PROP_TEMP) {
index 07e7945a1ff292048da586ac9709d17691a29fca..e97fc656a058c07d7c0c79a807cb3e04bec6dbf1 100644 (file)
@@ -253,9 +253,6 @@ struct charger_manager {
        struct device *dev;
        struct charger_desc *desc;
 
-       struct power_supply *fuel_gauge;
-       struct power_supply **charger_stat;
-
 #ifdef CONFIG_THERMAL
        struct thermal_zone_device *tzd_batt;
 #endif
index 3ed0496730229556921e3e77a5deeeecbb20bbac..096dbced02ac4b7cb9d18de6a8aa65e0592d78e9 100644 (file)
@@ -200,6 +200,12 @@ struct power_supply {
        void (*external_power_changed)(struct power_supply *psy);
        void (*set_charged)(struct power_supply *psy);
 
+       /*
+        * Set if thermal zone should not be created for this power supply.
+        * For example for virtual supplies forwarding calls to actual
+        * sensors or other supplies.
+        */
+       bool no_thermal;
        /* For APM emulation, think legacy userspace. */
        int use_for_apm;