ARM: dts: Update ti-sysc data for existing users
authorTony Lindgren <tony@atomide.com>
Fri, 12 Jan 2018 00:04:03 +0000 (16:04 -0800)
committerTony Lindgren <tony@atomide.com>
Fri, 12 Jan 2018 23:16:57 +0000 (15:16 -0800)
commite14d7e5320ebae9bffe4fbd585dfdd9d6de2550f
tree443b4e26cef69e71d3633d7a284d6574ce8d0c2d
parent7d9bfdac31d77305a28531033e604264ae3e449c
ARM: dts: Update ti-sysc data for existing users

Let's update the existing users with features and clock data as
specified in the binding. This is currently the smartreflex for most
part, and also few omap4 modules with no child device driver like
mcasp, abe iss and gfx.

Note that we had few mistakes that did not get noticed as we're still
probing the SmartReflex driver with legacy platform data and using
"ti,hwmods" legacy property for ti-sysc driver.

So let's fix the omap4 and dra7 smartreflex registers as there is no
no revision register.

And on omap4, the mcasp module has a revision register according to
the TRM.

And for omap34xx we need a different configuration compared to 36xx.
And the smartreflex on 3517 we've always kept disabled so let's
remove any references to it.

Signed-off-by: Tony Lindgren <tony@atomide.com>
arch/arm/boot/dts/am3517.dtsi
arch/arm/boot/dts/dra7.dtsi
arch/arm/boot/dts/omap3.dtsi
arch/arm/boot/dts/omap34xx.dtsi
arch/arm/boot/dts/omap36xx.dtsi
arch/arm/boot/dts/omap4.dtsi