1 Generic Thermal Sysfs driver How To
2 =========================
3
4 Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
5
6 Updated: 2 January 2008
7
8 Copyright (c)  2008 Intel Corporation
9
10
11 0. Introduction
12
13 The generic thermal sysfs provides a set of interfaces for thermal zone devices (sensors)
14 and thermal cooling devices (fan, processor...) to register with the thermal management
15 solution and to be a part of it.
16
17 This how-to focusses on enabling new thermal zone and cooling devices to participate
18 in thermal management.
19 This solution is platform independent and any type of thermal zone devices and
20 cooling devices should be able to make use of the infrastructure.
21
22 The main task of the thermal sysfs driver is to expose thermal zone attributes as well
23 as cooling device attributes to the user space.
24 An intelligent thermal management application can make decisions based on inputs
25 from thermal zone attributes (the current temperature and trip point temperature)
26 and throttle appropriate devices.
27
28 [0-*]   denotes any positive number starting from 0
29 [1-*]   denotes any positive number starting from 1
30
31 1. thermal sysfs driver interface functions
32
33 1.1 thermal zone device interface
34 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name, int trips,
35                                 void *devdata, struct thermal_zone_device_ops *ops)
36
37         This interface function adds a new thermal zone device (sensor) to
38         /sys/class/thermal folder as thermal_zone[0-*].
39         It tries to bind all the thermal cooling devices registered at the same time.
40
41         name: the thermal zone name.
42         trips: the total number of trip points this thermal zone supports.
43         devdata: device private data
44         ops: thermal zone device callbacks.
45                 .bind: bind the thermal zone device with a thermal cooling device.
46                 .unbind: unbing the thermal zone device with a thermal cooling device.
47                 .get_temp: get the current temperature of the thermal zone.
48                 .get_mode: get the current mode (user/kernel) of the thermal zone.
49                            "kernel" means thermal management is done in kernel.
50                            "user" will prevent kernel thermal driver actions upon trip points
51                            so that user applications can take charge of thermal management.
52                 .set_mode: set the mode (user/kernel) of the thermal zone.
53                 .get_trip_type: get the type of certain trip point.
54                 .get_trip_temp: get the temperature above which the certain trip point
55                                 will be fired.
56
57 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
58
59         This interface function removes the thermal zone device.
60         It deletes the corresponding entry form /sys/class/thermal folder and unbind all
61         the thermal cooling devices it uses.
62
63 1.2 thermal cooling device interface
64 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
65                                         void *devdata, struct thermal_cooling_device_ops *)
66
67         This interface function adds a new thermal cooling device (fan/processor/...) to
68         /sys/class/thermal/ folder as cooling_device[0-*].
69         It tries to bind itself to all the thermal zone devices register at the same time.
70         name: the cooling device name.
71         devdata: device private data.
72         ops: thermal cooling devices callbacks.
73                 .get_max_state: get the Maximum throttle state of the cooling device.
74                 .get_cur_state: get the Current throttle state of the cooling device.
75                 .set_cur_state: set the Current throttle state of the cooling device.
76
77 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
78
79         This interface function remove the thermal cooling device.
80         It deletes the corresponding entry form /sys/class/thermal folder and unbind
81         itself from all the thermal zone devices using it.
82
83 1.3 interface for binding a thermal zone device with a thermal cooling device
84 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
85                         int trip, struct thermal_cooling_device *cdev);
86
87         This interface function bind a thermal cooling device to the certain trip point
88         of a thermal zone device.
89         This function is usually called in the thermal zone device .bind callback.
90         tz: the thermal zone device
91         cdev: thermal cooling device
92         trip: indicates which trip point the cooling devices is associated with
93                  in this thermal zone.
94
95 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
96                                 int trip, struct thermal_cooling_device *cdev);
97
98         This interface function unbind a thermal cooling device from the certain trip point
99         of a thermal zone device.
100         This function is usually called in the thermal zone device .unbind callback.
101         tz: the thermal zone device
102         cdev: thermal cooling device
103         trip: indicates which trip point the cooling devices is associated with
104                 in this thermal zone.
105
106 2. sysfs attributes structure
107
108 RO      read only value
109 RW      read/write value
110
111 All thermal sysfs attributes will be represented under /sys/class/thermal
112 /sys/class/thermal/
113
114 Thermal zone device sys I/F, created once it's registered:
115 |thermal_zone[0-*]:
116         |-----type:                     Type of the thermal zone
117         |-----temp:                     Current temperature
118         |-----mode:                     Working mode of the thermal zone
119         |-----trip_point_[0-*]_temp:    Trip point temperature
120         |-----trip_point_[0-*]_type:    Trip point type
121
122 Thermal cooling device sys I/F, created once it's registered:
123 |cooling_device[0-*]:
124         |-----type :                    Type of the cooling device(processor/fan/...)
125         |-----max_state:                Maximum cooling state of the cooling device
126         |-----cur_state:                Current cooling state of the cooling device
127
128
129 These two dynamic attributes are created/removed in pairs.
130 They represent the relationship between a thermal zone and its associated cooling device.
131 They are created/removed for each
132 thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device successful exection.
133
134 |thermal_zone[0-*]
135         |-----cdev[0-*]:                The [0-*]th cooling device in the current thermal zone
136         |-----cdev[0-*]_trip_point:     Trip point that cdev[0-*] is associated with
137
138
139 ***************************
140 * Thermal zone attributes *
141 ***************************
142
143 type                            Strings which represent the thermal zone type.
144                                 This is given by thermal zone driver as part of registration.
145                                 Eg: "ACPI thermal zone" indicates it's a ACPI thermal device
146                                 RO
147                                 Optional
148
149 temp                            Current temperature as reported by thermal zone (sensor)
150                                 Unit: degree celsius
151                                 RO
152                                 Required
153
154 mode                            One of the predifned values in [kernel, user]
155                                 This file gives information about the algorithm
156                                 that is currently managing the thermal zone.
157                                 It can be either default kernel based algorithm
158                                 or user space application.
159                                 RW
160                                 Optional
161                                 kernel  = Thermal management in kernel thermal zone driver.
162                                 user    = Preventing kernel thermal zone driver actions upon
163                                           trip points so that user application can take full
164                                           charge of the thermal management.
165
166 trip_point_[0-*]_temp           The temperature above which trip point will be fired
167                                 Unit: degree celsius
168                                 RO
169                                 Optional
170
171 trip_point_[0-*]_type           Strings which indicate the type of the trip point
172                                 Eg. it can be one of critical, hot, passive,
173                                     active[0-*] for ACPI thermal zone.
174                                 RO
175                                 Optional
176
177 cdev[0-*]                       Sysfs link to the thermal cooling device node where the sys I/F
178                                 for cooling device throttling control represents.
179                                 RO
180                                 Optional
181
182 cdev[0-*]_trip_point            The trip point with which cdev[0-*] is assocated in this thermal zone
183                                 -1 means the cooling device is not associated with any trip point.
184                                 RO
185                                 Optional
186
187 ******************************
188 * Cooling device  attributes *
189 ******************************
190
191 type                            String which represents the type of device
192                                 eg: For generic ACPI: this should be "Fan",
193                                 "Processor" or "LCD"
194                                 eg. For memory controller device on intel_menlow platform:
195                                 this should be "Memory controller"
196                                 RO
197                                 Optional
198
199 max_state                       The maximum permissible cooling state of this cooling device.
200                                 RO
201                                 Required
202
203 cur_state                       The current cooling state of this cooling device.
204                                 the value can any integer numbers between 0 and max_state,
205                                 cur_state == 0 means no cooling
206                                 cur_state == max_state means the maximum cooling.
207                                 RW
208                                 Required
209
210 3. A simple implementation
211
212 ACPI thermal zone may support multiple trip points like critical/hot/passive/active.
213 If an ACPI thermal zone supports critical, passive, active[0] and active[1] at the same time,
214 it may register itself as a thermale_zone_device (thermal_zone1) with 4 trip points in all.
215 It has one processor and one fan, which are both registered as thermal_cooling_device.
216 If the processor is listed in _PSL method, and the fan is listed in _AL0 method,
217 the sys I/F structure will be built like this:
218
219 /sys/class/thermal:
220
221 |thermal_zone1:
222         |-----type:                     ACPI thermal zone
223         |-----temp:                     37
224         |-----mode:                     kernel
225         |-----trip_point_0_temp:        100
226         |-----trip_point_0_type:        critical
227         |-----trip_point_1_temp:        80
228         |-----trip_point_1_type:        passive
229         |-----trip_point_2_temp:        70
230         |-----trip_point_2_type:        active[0]
231         |-----trip_point_3_temp:        60
232         |-----trip_point_3_type:        active[1]
233         |-----cdev0:                    --->/sys/class/thermal/cooling_device0
234         |-----cdev0_trip_point:         1       /* cdev0 can be used for passive */
235         |-----cdev1:                    --->/sys/class/thermal/cooling_device3
236         |-----cdev1_trip_point:         2       /* cdev1 can be used for active[0]*/
237
238 |cooling_device0:
239         |-----type:                     Processor
240         |-----max_state:                8
241         |-----cur_state:                0
242
243 |cooling_device3:
244         |-----type:                     Fan