Merge tag 'hyperv-next-signed' of git://git.kernel.org/pub/scm/linux/kernel/git/hyper...
[sfrench/cifs-2.6.git] / Documentation / hwmon / inspur-ipsps1.rst
1 Kernel driver inspur-ipsps1
2 =======================
3
4 Supported chips:
5
6   * Inspur Power System power supply unit
7
8 Author: John Wang <wangzqbj@inspur.com>
9
10 Description
11 -----------
12
13 This driver supports Inspur Power System power supplies. This driver
14 is a client to the core PMBus driver.
15
16 Usage Notes
17 -----------
18
19 This driver does not auto-detect devices. You will have to instantiate the
20 devices explicitly. Please see Documentation/i2c/instantiating-devices for
21 details.
22
23 Sysfs entries
24 -------------
25
26 The following attributes are supported:
27
28 ======================= ======================================================
29 curr1_input             Measured input current
30 curr1_label             "iin"
31 curr1_max               Maximum current
32 curr1_max_alarm         Current high alarm
33 curr2_input             Measured output current in mA.
34 curr2_label             "iout1"
35 curr2_crit              Critical maximum current
36 curr2_crit_alarm        Current critical high alarm
37 curr2_max               Maximum current
38 curr2_max_alarm         Current high alarm
39
40 fan1_alarm              Fan 1 warning.
41 fan1_fault              Fan 1 fault.
42 fan1_input              Fan 1 speed in RPM.
43
44 in1_alarm               Input voltage under-voltage alarm.
45 in1_input               Measured input voltage in mV.
46 in1_label               "vin"
47 in2_input               Measured output voltage in mV.
48 in2_label               "vout1"
49 in2_lcrit               Critical minimum output voltage
50 in2_lcrit_alarm         Output voltage critical low alarm
51 in2_max                 Maximum output voltage
52 in2_max_alarm           Output voltage high alarm
53 in2_min                 Minimum output voltage
54 in2_min_alarm           Output voltage low alarm
55
56 power1_alarm            Input fault or alarm.
57 power1_input            Measured input power in uW.
58 power1_label            "pin"
59 power1_max              Input power limit
60 power2_max_alarm        Output power high alarm
61 power2_max              Output power limit
62 power2_input            Measured output power in uW.
63 power2_label            "pout"
64
65 temp[1-3]_input         Measured temperature
66 temp[1-2]_max           Maximum temperature
67 temp[1-3]_max_alarm     Temperature high alarm
68
69 vendor                  Manufacturer name
70 model                   Product model
71 part_number             Product part number
72 serial_number           Product serial number
73 fw_version              Firmware version
74 hw_version              Hardware version
75 mode                    Work mode. Can be set to active or
76                         standby, when set to standby, PSU will
77                         automatically switch between standby