debug: Fix WARN_ON_ONCE() for modules
[sfrench/cifs-2.6.git] / Documentation / devicetree / bindings / thermal / brcm,ns-thermal.txt
1 * Broadcom Northstar Thermal
2
3 This binding describes thermal sensor that is part of Northstar's DMU (Device
4 Management Unit).
5
6 Required properties:
7 - compatible : Must be "brcm,ns-thermal"
8 - reg : iomem address range of PVTMON registers
9 - #thermal-sensor-cells : Should be <0>
10
11 Example:
12
13 thermal: thermal@1800c2c0 {
14         compatible = "brcm,ns-thermal";
15         reg = <0x1800c2c0 0x10>;
16         #thermal-sensor-cells = <0>;
17 };
18
19 thermal-zones {
20         cpu_thermal: cpu-thermal {
21                 polling-delay-passive = <0>;
22                 polling-delay = <1000>;
23                 coefficients = <(-556) 418000>;
24                 thermal-sensors = <&thermal>;
25
26                 trips {
27                         cpu-crit {
28                                 temperature     = <125000>;
29                                 hysteresis      = <0>;
30                                 type            = "critical";
31                         };
32                 };
33
34                 cooling-maps {
35                 };
36         };
37 };