1 Voltage/Current Regulators
2
3 Optional properties:
4 - regulator-name: A string used as a descriptive name for regulator outputs
5 - regulator-min-microvolt: smallest voltage consumers may set
6 - regulator-max-microvolt: largest voltage consumers may set
7 - regulator-microvolt-offset: Offset applied to voltages to compensate for voltage drops
8 - regulator-min-microamp: smallest current consumers may set
9 - regulator-max-microamp: largest current consumers may set
10 - regulator-input-current-limit-microamp: maximum input current regulator allows
11 - regulator-always-on: boolean, regulator should never be disabled
12 - regulator-boot-on: bootloader/firmware enabled regulator
13 - regulator-allow-bypass: allow the regulator to go into bypass mode
14 - regulator-allow-set-load: allow the regulator performance level to be configured
15 - <name>-supply: phandle to the parent supply/regulator node
16 - regulator-ramp-delay: ramp delay for regulator(in uV/us)
17   For hardware which supports disabling ramp rate, it should be explicitly
18   initialised to zero (regulator-ramp-delay = <0>) for disabling ramp delay.
19 - regulator-enable-ramp-delay: The time taken, in microseconds, for the supply
20   rail to reach the target voltage, plus/minus whatever tolerance the board
21   design requires. This property describes the total system ramp time
22   required due to the combination of internal ramping of the regulator itself,
23   and board design issues such as trace capacitance and load on the supply.
24 - regulator-settling-time-us: Settling time, in microseconds, for voltage
25   change if regulator have the constant time for any level voltage change.
26   This is useful when regulator have exponential voltage change.
27 - regulator-settling-time-up-us: Settling time, in microseconds, for voltage
28   increase if the regulator needs a constant time to settle after voltage
29   increases of any level. This is useful for regulators with exponential
30   voltage changes.
31 - regulator-settling-time-down-us: Settling time, in microseconds, for voltage
32   decrease if the regulator needs a constant time to settle after voltage
33   decreases of any level. This is useful for regulators with exponential
34   voltage changes.
35 - regulator-soft-start: Enable soft start so that voltage ramps slowly
36 - regulator-state-mem sub-root node for Suspend-to-RAM mode
37   : suspend to memory, the device goes to sleep, but all data stored in memory,
38   only some external interrupt can wake the device.
39 - regulator-state-disk sub-root node for Suspend-to-DISK mode
40   : suspend to disk, this state operates similarly to Suspend-to-RAM,
41   but includes a final step of writing memory contents to disk.
42 - regulator-state-[mem/disk] node has following common properties:
43         - regulator-on-in-suspend: regulator should be on in suspend state.
44         - regulator-off-in-suspend: regulator should be off in suspend state.
45         - regulator-suspend-microvolt: regulator should be set to this voltage
46           in suspend.
47         - regulator-mode: operating mode in the given suspend state.
48           The set of possible operating modes depends on the capabilities of
49           every hardware so the valid modes are documented on each regulator
50           device tree binding document.
51 - regulator-initial-mode: initial operating mode. The set of possible operating
52   modes depends on the capabilities of every hardware so each device binding
53   documentation explains which values the regulator supports.
54 - regulator-system-load: Load in uA present on regulator that is not captured by
55   any consumer request.
56 - regulator-pull-down: Enable pull down resistor when the regulator is disabled.
57 - regulator-over-current-protection: Enable over current protection.
58 - regulator-active-discharge: tristate, enable/disable active discharge of
59   regulators. The values are:
60         0: Disable active discharge.
61         1: Enable active discharge.
62         Absence of this property will leave configuration to default.
63
64 Deprecated properties:
65 - regulator-compatible: If a regulator chip contains multiple
66   regulators, and if the chip's binding contains a child node that
67   describes each regulator, then this property indicates which regulator
68   this child node is intended to configure. If this property is missing,
69   the node's name will be used instead.
70
71 Example:
72
73         xyzreg: regulator@0 {
74                 regulator-min-microvolt = <1000000>;
75                 regulator-max-microvolt = <2500000>;
76                 regulator-always-on;
77                 vin-supply = <&vin>;
78
79                 regulator-state-mem {
80                         regulator-on-in-suspend;
81                 };
82         };
83
84 Regulator Consumers:
85 Consumer nodes can reference one or more of its supplies/
86 regulators using the below bindings.
87
88 - <name>-supply: phandle to the regulator node
89
90 These are the same bindings that a regulator in the above
91 example used to reference its own supply, in which case
92 its just seen as a special case of a regulator being a
93 consumer itself.
94
95 Example of a consumer device node (mmc) referencing two
96 regulators (twl_reg1 and twl_reg2),
97
98         twl_reg1: regulator@0 {
99                 ...
100                 ...
101                 ...
102         };
103
104         twl_reg2: regulator@1 {
105                 ...
106                 ...
107                 ...
108         };
109
110         mmc: mmc@0 {
111                 ...
112                 ...
113                 vmmc-supply = <&twl_reg1>;
114                 vmmcaux-supply = <&twl_reg2>;
115         };