1 Bindings for MAX6651 and MAX6650 I2C fan controllers
2
3 Reference:
4 [1]     https://datasheets.maximintegrated.com/en/ds/MAX6650-MAX6651.pdf
5
6 Required properties:
7 - compatible : One of "maxim,max6650" or "maxim,max6651"
8 - reg        : I2C address, one of 0x1b, 0x1f, 0x4b, 0x48.
9
10 Optional properties, default is to retain the chip's current setting:
11 - maxim,fan-microvolt : The supply voltage of the fan, either 5000000 uV or
12                         12000000 uV.
13 - maxim,fan-prescale  : Pre-scaling value, as per datasheet [1]. Lower values
14                         allow more fine-grained control of slower fans.
15                         Valid: 1, 2, 4, 8, 16.
16 - maxim,fan-target-rpm: Initial requested fan rotation speed. If specified, the
17                         driver selects closed-loop mode and the requested speed.
18                         This ensures the fan is already running before userspace
19                         takes over.
20
21 Example:
22         fan-max6650: max6650@1b {
23                 reg = <0x1b>;
24                 compatible = "maxim,max6650";
25                 maxim,fan-microvolt = <12000000>;
26                 maxim,fan-prescale = <4>;