net/mlx5: Avoid cleaning flow steering table twice during error flow
authorTalat Batheesh <talatb@mellanox.com>
Sun, 15 Apr 2018 08:26:19 +0000 (11:26 +0300)
committerSaeed Mahameed <saeedm@mellanox.com>
Thu, 26 Apr 2018 19:43:20 +0000 (12:43 -0700)
When we fail to initialize the RX root namespace, we need
to clean only that and not the entire flow steering.

Currently the code may try to clean the flow steering twice
on error witch leads to null pointer deference.
Make sure we clean correctly.

Fixes: fba53f7b5719 ("net/mlx5: Introduce mlx5_flow_steering structure")
Signed-off-by: Talat Batheesh <talatb@mellanox.com>
Reviewed-by: Mark Bloch <markb@mellanox.com>
Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
drivers/net/ethernet/mellanox/mlx5/core/fs_core.c

index de51e7c39bc8b8ae02ea236afc9286b6e768cce5..2595c67ea39e228b8ecfdfc711891e9a183bb48e 100644 (file)
@@ -187,6 +187,7 @@ static void del_sw_ns(struct fs_node *node);
 static void del_sw_hw_rule(struct fs_node *node);
 static bool mlx5_flow_dests_cmp(struct mlx5_flow_destination *d1,
                                struct mlx5_flow_destination *d2);
+static void cleanup_root_ns(struct mlx5_flow_root_namespace *root_ns);
 static struct mlx5_flow_rule *
 find_flow_rule(struct fs_fte *fte,
               struct mlx5_flow_destination *dest);
@@ -2351,23 +2352,27 @@ static int create_anchor_flow_table(struct mlx5_flow_steering *steering)
 
 static int init_root_ns(struct mlx5_flow_steering *steering)
 {
+       int err;
+
        steering->root_ns = create_root_ns(steering, FS_FT_NIC_RX);
        if (!steering->root_ns)
-               goto cleanup;
+               return -ENOMEM;
 
-       if (init_root_tree(steering, &root_fs, &steering->root_ns->ns.node))
-               goto cleanup;
+       err = init_root_tree(steering, &root_fs, &steering->root_ns->ns.node);
+       if (err)
+               goto out_err;
 
        set_prio_attrs(steering->root_ns);
-
-       if (create_anchor_flow_table(steering))
-               goto cleanup;
+       err = create_anchor_flow_table(steering);
+       if (err)
+               goto out_err;
 
        return 0;
 
-cleanup:
-       mlx5_cleanup_fs(steering->dev);
-       return -ENOMEM;
+out_err:
+       cleanup_root_ns(steering->root_ns);
+       steering->root_ns = NULL;
+       return err;
 }
 
 static void clean_tree(struct fs_node *node)