Supported chips:
- * Fintek F71882FG and F71883FG
- Prefix: 'f71882fg'
+ * Fintek F71858FG
+ Prefix: 'f71858fg'
Addresses scanned: none, address read from Super I/O config space
Datasheet: Available from the Fintek website
* Fintek F71862FG and F71863FG
Prefix: 'f71862fg'
Addresses scanned: none, address read from Super I/O config space
Datasheet: Available from the Fintek website
+ * Fintek F71882FG and F71883FG
+ Prefix: 'f71882fg'
+ Addresses scanned: none, address read from Super I/O config space
+ Datasheet: Available from the Fintek website
* Fintek F8000
Prefix: 'f8000'
Addresses scanned: none, address read from Super I/O config space
Three different fan control modes are supported; the mode number is written
to the pwm#_enable file. Note that not all modes are supported on all
-chips, and some modes may only be available in RPM / PWM mode on the F8000.
+chips, and some modes may only be available in RPM / PWM mode.
Writing an unsupported mode will result in an invalid parameter error.
* 1: Manual mode
You ask for a specific PWM duty cycle / DC voltage or a specific % of
fan#_full_speed by writing to the pwm# file. This mode is only
- available on the F8000 if the fan channel is in RPM mode.
+ available on the F71858FG / F8000 if the fan channel is in RPM mode.
* 2: Normal auto mode
You can define a number of temperature/fan speed trip points, which % the