Merge tag 'v4.20' into next
[sfrench/cifs-2.6.git] / Documentation / devicetree / bindings / regulator / max8997-regulator.txt
1 * Maxim MAX8997 Voltage and Current Regulator
2
3 The Maxim MAX8997 is a multi-function device which includes voltage and
4 current regulators, rtc, charger controller and other sub-blocks. It is
5 interfaced to the host controller using a i2c interface. Each sub-block is
6 addressed by the host system using different i2c slave address. This document
7 describes the bindings for 'pmic' sub-block of max8997.
8
9 Required properties:
10 - compatible: Should be "maxim,max8997-pmic".
11 - reg: Specifies the i2c slave address of the pmic block. It should be 0x66.
12
13 - max8997,pmic-buck1-dvs-voltage: A set of 8 voltage values in micro-volt (uV)
14   units for buck1 when changing voltage using gpio dvs. Refer to [1] below
15   for additional information.
16
17 - max8997,pmic-buck2-dvs-voltage: A set of 8 voltage values in micro-volt (uV)
18   units for buck2 when changing voltage using gpio dvs. Refer to [1] below
19   for additional information.
20
21 - max8997,pmic-buck5-dvs-voltage: A set of 8 voltage values in micro-volt (uV)
22   units for buck5 when changing voltage using gpio dvs. Refer to [1] below
23   for additional information.
24
25 [1] If none of the 'max8997,pmic-buck[1/2/5]-uses-gpio-dvs' optional
26     property is specified, the 'max8997,pmic-buck[1/2/5]-dvs-voltage'
27     property should specify atleast one voltage level (which would be a
28     safe operating voltage).
29
30     If either of the 'max8997,pmic-buck[1/2/5]-uses-gpio-dvs' optional
31     property is specified, then all the eight voltage values for the
32     'max8997,pmic-buck[1/2/5]-dvs-voltage' should be specified.
33
34 Optional properties:
35 - interrupts: Interrupt specifiers for two interrupt sources.
36   - First interrupt specifier is for 'irq1' interrupt.
37   - Second interrupt specifier is for 'alert' interrupt.
38 - max8997,pmic-buck1-uses-gpio-dvs: 'buck1' can be controlled by gpio dvs.
39 - max8997,pmic-buck2-uses-gpio-dvs: 'buck2' can be controlled by gpio dvs.
40 - max8997,pmic-buck5-uses-gpio-dvs: 'buck5' can be controlled by gpio dvs.
41
42 Additional properties required if either of the optional properties are used:
43 - max8997,pmic-ignore-gpiodvs-side-effect: When GPIO-DVS mode is used for
44   multiple bucks, changing the voltage value of one of the bucks may affect
45   that of another buck, which is the side effect of the change (set_voltage).
46   Use this property to ignore such side effects and change the voltage.
47
48 - max8997,pmic-buck125-default-dvs-idx: Default voltage setting selected from
49   the possible 8 options selectable by the dvs gpios. The value of this
50   property should be between 0 and 7. If not specified or if out of range, the
51   default value of this property is set to 0.
52
53 - max8997,pmic-buck125-dvs-gpios: GPIO specifiers for three host gpio's used
54   for dvs. The format of the gpio specifier depends in the gpio controller.
55
56 Regulators: The regulators of max8997 that have to be instantiated should be
57 included in a sub-node named 'regulators'. Regulator nodes included in this
58 sub-node should be of the format as listed below.
59
60         regulator_name {
61                 standard regulator bindings here
62         };
63
64 The following are the names of the regulators that the max8997 pmic block
65 supports. Note: The 'n' in LDOn and BUCKn represents the LDO or BUCK number
66 as per the datasheet of max8997.
67
68         - LDOn
69                   - valid values for n are 1 to 18 and 21
70                   - Example: LDO0, LD01, LDO2, LDO21
71         - BUCKn
72                   - valid values for n are 1 to 7.
73                   - Example: BUCK1, BUCK2, BUCK3, BUCK7
74
75         - ENVICHG: Battery Charging Current Monitor Output. This is a fixed
76                    voltage type regulator
77
78         - ESAFEOUT1: (ldo19)
79         - ESAFEOUT2: (ld020)
80
81         - CHARGER_CV: main battery charger voltage control
82         - CHARGER: main battery charger current control
83         - CHARGER_TOPOFF: end of charge current threshold level
84
85 The bindings inside the regulator nodes use the standard regulator bindings
86 which are documented elsewhere.
87
88 Example:
89
90         max8997_pmic@66 {
91                 compatible = "maxim,max8997-pmic";
92                 interrupt-parent = <&wakeup_eint>;
93                 reg = <0x66>;
94                 interrupts = <4 0>, <3 0>;
95
96                 max8997,pmic-buck1-uses-gpio-dvs;
97                 max8997,pmic-buck2-uses-gpio-dvs;
98                 max8997,pmic-buck5-uses-gpio-dvs;
99
100                 max8997,pmic-ignore-gpiodvs-side-effect;
101                 max8997,pmic-buck125-default-dvs-idx = <0>;
102
103                 max8997,pmic-buck125-dvs-gpios = <&gpx0 0 1 0 0>, /* SET1 */
104                                                  <&gpx0 1 1 0 0>, /* SET2 */
105                                                  <&gpx0 2 1 0 0>; /* SET3 */
106
107                 max8997,pmic-buck1-dvs-voltage = <1350000>, <1300000>,
108                                                  <1250000>, <1200000>,
109                                                  <1150000>, <1100000>,
110                                                  <1000000>, <950000>;
111
112                 max8997,pmic-buck2-dvs-voltage = <1100000>, <1100000>,
113                                                  <1100000>, <1100000>,
114                                                  <1000000>, <1000000>,
115                                                  <1000000>, <1000000>;
116
117                 max8997,pmic-buck5-dvs-voltage = <1200000>, <1200000>,
118                                                  <1200000>, <1200000>,
119                                                  <1200000>, <1200000>,
120                                                  <1200000>, <1200000>;
121
122                 regulators {
123                         ldo1_reg: LDO1 {
124                                 regulator-name = "VDD_ABB_3.3V";
125                                 regulator-min-microvolt = <3300000>;
126                                 regulator-max-microvolt = <3300000>;
127                         };
128
129                         ldo2_reg: LDO2 {
130                                 regulator-name = "VDD_ALIVE_1.1V";
131                                 regulator-min-microvolt = <1100000>;
132                                 regulator-max-microvolt = <1100000>;
133                                 regulator-always-on;
134                         };
135
136                         buck1_reg: BUCK1 {
137                                 regulator-name = "VDD_ARM_1.2V";
138                                 regulator-min-microvolt = <950000>;
139                                 regulator-max-microvolt = <1350000>;
140                                 regulator-always-on;
141                                 regulator-boot-on;
142                         };
143                 };
144         };