HID: i2c-hid: fix no irq after reset on raydium 3118
authorAaron Ma <aaron.ma@canonical.com>
Wed, 13 Nov 2019 19:12:47 +0000 (03:12 +0800)
committerJiri Kosina <jkosina@suse.cz>
Fri, 15 Nov 2019 15:19:03 +0000 (16:19 +0100)
commit0c8432236dea20a95f68fa17989ea3f8af0186a5
tree5f1a882d21cff9447ec1264b1e732841e9d85675
parentf1a0094cbbe97a5f8aca7bdc64bfe43ac9dc6879
HID: i2c-hid: fix no irq after reset on raydium 3118

On some ThinkPad L390 some raydium 3118 touchscreen devices
doesn't response any data after reset, but some does.

Add this ID to no irq quirk,
then don't wait for any response alike on these touchscreens.
All kinds of raydium 3118 devices work fine.

BugLink: https://bugs.launchpad.net/bugs/1849721
Signed-off-by: Aaron Ma <aaron.ma@canonical.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
drivers/hid/hid-ids.h
drivers/hid/i2c-hid/i2c-hid-core.c