hwmon: (ftsteutates) Replace fanX_source with pwmX_auto_channels_temp
[sfrench/cifs-2.6.git] / Documentation / hwmon / ftsteutates.rst
index 198fa8e2819dad91bb05aae94d761a286fd0b032..b3bfec36661dc4eb96085859058cf2fc663b2076 100644 (file)
@@ -22,6 +22,11 @@ enhancements. It can monitor up to 4 voltages, 16 temperatures and
 8 fans. It also contains an integrated watchdog which is currently
 implemented in this driver.
 
+The ``pwmX_auto_channels_temp`` attributes show which temperature sensor
+is currently driving which fan channel. This value might dynamically change
+during runtime depending on the temperature sensor selected by
+the fan control circuit.
+
 The 4 voltages require a board-specific multiplier, since the BMC can
 only measure voltages up to 3.3V and thus relies on voltage dividers.
 Consult your motherboard manual for details.